Power

Kidde KN-COB-LP2 Battery CO Alarm Review: Uses and Limits

Kidde battery-powered carbon monoxide alarm KN-COB-LP2, white, front view
Image: Kidde, https://www.kidde.com/products/carbon-monoxide-alarms/battery-carbon-monoxide-alarm-with-hush

Every hurricane season, the deaths that follow the storm outnumber the deaths from the storm itself, and carbon monoxide from portable generators is one of the leading causes. The pattern is always the same: the power is out, it is hot, the generator gets moved a little closer to the house to keep the cord short or the rain off, and a family goes to sleep with an engine running under a window or in an attached garage. A battery-powered carbon monoxide alarm is the cheapest thing you can buy that breaks that chain, and the Kidde KN-COB-LP2 is the simplest version of it.

This review covers the Amazon listing that sells the alarm as a six-pack, which sounds like a lot until you count the places one belongs: each sleeping level of the house, the hallway outside the bedrooms, the room where the generator cord comes in, the garage apartment, the RV or camper, and the relatives’ house you may ride out the storm in. Six is about right for a household that takes generator season seriously.

Who Needs Battery-Backed CO Detection

Anyone who owns, borrows or plans to buy a gasoline, propane or dual-fuel generator. That includes the inverter units with built-in carbon monoxide shutoff, such as the Champion 4500W we reviewed. A shutoff on the generator protects the area around the generator. An alarm in the bedroom protects the people in it, and the two measure different air.

A CO alarm does not make an outdoor stove, grill or generator safe to use indoors. Each of those produces carbon monoxide, and none of them give any warning you can smell.

Finally, it is for the household whose only CO alarm is a plug-in unit. Plug-in alarms with no battery backup go dark with the power, which is precisely when the generator starts. A battery alarm fills that gap.

Key Specs

Spec Kidde KN-COB-LP2
Power 2 AA batteries, included; no wiring
Sensor Electrochemical carbon monoxide sensor
Alarm 85 dB at 10 ft, red LED; green LED shows power
Controls Test/Hush button, event memory of the last CO detection or test
Mounting Wall mount or tabletop, 4.5 x 2.75 x 1.5 in
Listing UL 2034 listed
Warranty 10-year limited (alarm, not batteries)
Pack 6 alarms in this listing

Figures are from Kidde’s listing and documentation. Carbon monoxide alarms have a fixed service life; Kidde’s current units signal end of life with a chirp pattern, and the date to replace them is printed on the back.

What We Like

It works when the power does not. There is no cord, no outlet and nothing to install beyond two screws or a flat surface. During an outage it keeps watch exactly the same as it did the day before, which is the whole point.

Electrochemical sensing is the right technology. This is the sensor type used in professional CO meters. It responds to the sustained, moderate concentrations that make people drowsy before they make them sick, not just the acute levels that would be obvious anyway.

The event memory answers the question you will have. If the alarm sounded while you were out, pressing the button tells you whether it detected CO or someone tested it. In a house full of people running extension cords and fuel appliances, that record matters.

Loud enough to wake a sleeping adult. At 85 decibels from ten feet, it is the same level as a smoke alarm, and the sound pattern (four beeps, pause) is distinct from a smoke alarm’s three.

Portable by design. Because it sits on a tabletop, you can move one to wherever the risk is tonight: the room where the generator cord comes in, the camper, a relative’s house. Kidde markets this model for travel for the same reason.

The six-pack solves the coverage problem. A single alarm near the generator cord is better than nothing, but carbon monoxide travels through a house and pools where people sleep. Plan alarm coverage using the manufacturer’s installation instructions and applicable requirements, then choose the pack size.

Limitations

It is not a smoke alarm. This unit detects carbon monoxide only. You still need smoke alarms, and a combination unit is a reasonable choice if you want to reduce clutter. Keep them separate if you prefer the simplicity of an AA battery device you can carry.

Batteries need a schedule. The alarm chirps when the batteries run low, but a chirp at 3 a.m. in the week after a storm is the wrong time to find out. Change them when you change smoke alarm batteries, and keep a spare set of AAs in the generator kit.

It has a shelf life. Like every CO alarm, the sensor degrades over time and the unit must be replaced when it signals end of life. Write the install date on it with a marker.

No digital readout. Some alarms display the CO concentration in parts per million, which helps you judge how serious a situation is. This model lacks a concentration display; an absence of an alarm is not a general assurance that the air is safe. For most households that is fine; if you want numbers, Kidde’s digital display models cost more and show them.

Placement matters more than people think. It belongs at head height in a bedroom or hallway, at least 15 feet from fuel-burning appliances to avoid nuisance alarms, and never in a bathroom or directly above a stove. Read the placement sheet; it is one page.

Alternatives

A plug-in CO alarm with battery backup. Kidde and First Alert both sell wall-outlet units that fall back to a 9V or AA battery. They are a good primary alarm for the house, but the backup battery is often dead from neglect, and you cannot carry them to the camper. We would own one of these and several of the battery units.

A combination smoke and CO alarm. Fewer devices on the ceiling, one battery schedule. The trade is that ceiling placement is ideal for smoke and merely acceptable for CO. If you go this route, still put a dedicated CO alarm in the room nearest the generator cord.

A generator with built-in CO shutoff. The Champion 4500W inverter shuts itself down if CO builds up around it, and that feature has saved lives. It is a complement to an indoor alarm, not a replacement. The sensor on the generator does not know what the air in your bedroom looks like.

For placement rules, refueling habits and the twenty-foot rule, read our generator safety guide. If you run a larger open-frame unit like the Firman tri-fuel generator, the same rules apply with less margin for error.

Common Questions

Where should I put a CO alarm when running a generator?

One in or just outside each bedroom, at roughly head height, plus one in the room where the generator’s extension cord enters the house. The generator itself should be at least 20 feet from any door, window or vent, with the exhaust pointed away from the building.

Will it go off from a gas stove or a candle?

A properly working gas stove in a ventilated kitchen rarely triggers a CO alarm, and candles do not produce enough CO to matter. Repeated alarms near a stove or water heater mean something is burning incompletely and should be checked, not that the alarm is faulty.

How long do the batteries last?

Kidde rates the included AAs for roughly a year of normal operation. The unit chirps when they run low. Replace them on a fixed date each year and keep spares with the generator.

Bottom Line

If you own a generator and do not own a battery-powered carbon monoxide alarm, fix that before you buy anything else on this site. The Kidde KN-COB-LP2 is simple, loud, reliable, and runs on batteries you already have. The six-pack covers every sleeping level and every fuel source in a typical home with a couple left over for the camper or a neighbor. It is the least expensive thing in the generator kit and the one most likely to save a life.

Some links on this page are Amazon affiliate links. If you buy through them, Ultimate Prepper’s Guide may earn a small commission at no extra cost to you.